Product
- Detachable plate heat exchanger
- Domestic plate heat exchanger seal gasket
- Semi welded plate heat exchanger
- Brazed plate heat exchanger
- Welded plate heat exchanger
- Detachable frame
- Heat recovery / heat exchange unit
- Wire winding hydraulic press
Hot news
Welded plate heat exchanger
OMG all-welded plate heat exchanger type main parameters | |||||||||
OMG model |
Monolithic heat transfer area m² |
Maximum assembly area m² |
Maximum water treatment capacity m³/h |
Working pressure Mpa |
Operating temperature ℃ |
Plate spacing |
Flow cross-sectional area m² |
Diameter mm |
|
Character plate |
QH-A | 0.02-1.4 | 2-1000 | 5-2500 | ≤3.0 | ≤300 | 2.5-4.5 | 0.00036-0.00261 | 20-600 |
QH-B | 0.02-1.4 | 2-1000 | 5-2500 | ≤3.0 | ≤300 | 2.5-4.5 | 0.00036-0.00261 | 20-600 | |
QH-C | 0.02-1.4 | 2-1000 | 5-2500 | ≤3.0 | ≤300 | 2.5-4.5 | 0.00036-0.00261 | 20-600 | |
QH-D | 0.02-1.4 | 2-1000 | 5-2500 | ≤3.0 | ≤300 | 2.5-4.5 | 0.00036-0.00261 | 20-600 | |
Wide flow plate |
QH-E | 0.2-2.8 | 5-1500 | 20-4000 | ≤2.5 | ≤300 | 5-10.0 | 0.0012-0.008 | 20-800 |
QH-F | 0.2-2.8 | 5-1500 | 20-4000 | ≤2.5 | ≤300 | 5-10.0 | 0.0012-0.008 | 20-800 | |
QH-G | 0.2-2.8 | 5-1500 | 20-4000 | ≤2.5 | ≤300 | 5-10.0 | 0.0012-0.008 | 20-800 | |
QH-H | 0.2-2.8 | 5-1500 | 20-4000 | ≤2.5 | ≤300 | 5-10.0 | 0.0012-0.008 | 20-800 | |
Note: 1, the above product data for reference only, accurate product data to our company's product design books and product drawings shall prevail. 2, the above products for my company to push the main product line, the company can also provide a variety of other models of products, product details, please contact our technical department for consultation. |
|||||||||
product description
All-welded heat exchanger heat exchanger plate, is made of special stainless steel, made of special mold. Smooth surface is not easy to scale. Its unique ripple design allows the fluid at a lower flow rate can also produce turbulence, high heat transfer efficiency, the entire plate bundle all the use of bulk materials welded by welding. Do not use any non-metallic sealing material, which has a high temperature, pressure performance. Can be widely used in petroleum, chemical, pharmaceutical, electricity, food and other industries.
Advantages: Unique high-strength welding plate heat exchanger products, compact structure, no gasket between the board, high temperature, high pressure, high heat transfer efficiency.
Characteristics of Full Welded Heat Exchanger
1, compact structure, small footprint, high heat transfer efficiency, high pressure capacity (up to 4.0Mpa), high temperature (maximum temperature up to 250 ~ 300 ℃), reliable operation.
2, high heat transfer efficiency: heat exchanger medium heat exchange is achieved through the beam bundle, the composition of the board plate by the special mold compression molding, similar to the general form of removable plate heat exchanger, with heat transfer High efficiency, high flow, small pressure drop, less heat loss and so on.
3, flexible and convenient: with a set of molds can be pressed different lengths of the board, composed of different specifications board beam, the formation of the same width of the product line, specifications and more models, choice, to better meet the demand conditions.
4, the scope of application: board and compression board all used a welding structure, for the temperature ≤ 300 ℃, pressure ≤ 4.0Mpa or working medium on the sealing gasket corrosion and flammable, explosive, toxic media And the environmental requirements of high safety in the production process of steam condensation, liquid medium cooling, heating, evaporation and other conditions under safe and smooth operation. Therefore, both with the advantages of removable plate heat exchanger, but also with the application of high temperature, high pressure characteristics.
Application areas
Widely used in crude oil, natural gas purification and chemical products; chemical industry; pharmaceutical and specific chemicals; jet control system; HVAC, regional heating, thermal power plant; food technology; cooling tower heat recovery.